1blinkingBLUELED:Whentheremainingbatterycapacityisreached,itispossibletoswitchovertotheenergysparing
lamp(remaininglightduration>2h)
Emergencylightfunction:(powerfailureelectronics)
Shouldthepowersupplyfailwhilethelampisparkedinthewallbracketforcharging,themainlampbeginstoburn
untilthesupplyvoltagehasbeenrestoredorthedischargelimitofthebatteryisreached.Itispossibletoswitcho
theportablesearchlightmanually.
Repairandmaintenance:
Repairworkmayonlybecarriedoutbyprofessionallytrainedelectricians!
Onlyoriginalreplacementpartsmaybeused!
> Disengage(2)switches,leftandrightonthebase.
> Removetheoldbattery.
> Insertthenewbattery.
> Re-engagethetwoswitches,leftandrightonthebase.
Usedbatteriesshouldbebroughttorecyclinganddonotbelongwiththehouseholdgarbage!
1. Batterycapacitydisplaythrough4BLUELED.
2. Operationselectioncontrolswitch.
3. ChargesocketInput12V-24V.
4. Wallbracketwithintegratedchargingelectronics.
5. Searchlightheadwithhalogenlamp.
6. Energysavinglampwith4highperformanceLEDsontheundersideoftheportablesearchlight.
7. Colourltersattachmentavailableasanoption.(orangeandred–NOTincludedinthescopeofsupply).
9. Housingwithintegratedlampcontrolsystem.
Pleaseproceedasfollows:
> Openthelampringsbypressingtheswitchonthelampheadupperside
> Carefullyremovethelampringwiththereector
> Cautiouslyremovethelamp,forwards
> Graspthenewlampwithcloth,andinsertitintotheprescribedopening
> Insertthereector,whilepayingcarefulattentionthatthegivenlampisnotdamaged
> Whenclosingthelampring,paycarefulattentionthattheundersideisattachedrst,andthatafterwardsthe
uppersideispresseduntilitcatches.